Here you can find the most frequent asked questions to the programs related with the waste water.
HYKAS
KAREL
REBECK
RS138
HYKAS
Which interpolation should I use for the calculation of rainfall ?
In KOSTRA-Atlas, the rainfall from sampling points are always taken with interpolation. Meanwhile does this interpolation method have sufficient alternatives ?
In 1997, a double logarithmic interpolation method from DWD for u(D) and w(D) was developed. This method has a scope upto D=15 in comparision with other interpolation methods having higher rain duration.
10/2003: The working group HW 1.1 "Precipitation" recommended the application of hyperbolic interpolation methods for the area I. Grund: For the high rainfall duration, using double-logarithmic interpolation methods- Extrapolation(D<15 Minutes). This is comparable with other interpolation methods regarding the rainfall durations (Futher informations can be seen in "Modifizierung des Berechnungsverfahren der statistischen 5- und 10-min-Werte in KOSTRA", Universität Hannover - Institut für Wasserwirtschaft, Hydrologie und landwirtschaftlichen Wasserbau).
Since11/2005, combination of both the above methods are used. With an update by Deutsche weather services (DWD), again, a corrected computation variant using KOSTRA-rainfall duration is published. According to DWD, since 11/2005 it is recommended that for short duration computation (Computing I, D = 5 to D = 60 Minutes) , the hyperbolic parameter for u(D) and the double logarithmic parameter for w(D) are used. In Hykas, these interpolations methods are denoed as KOSTRA-DWD-2000.
Hykas requires very small &Delta T for computation,-Should it be like that?
Using unsteady calculation, due to Courant-requirement, recommends for determination of ΔT. Representation for a small ΔT is u. A. the length of pipe. Very short pipe results a very small ΔT. For the plausibility control, the system can simply be checked with short pipeline (< 5m). When the pipeline can not be elongated to fit with the model, then there is a possibility of a virtual pipeline, where a ΔT is to be given. Then by Hykas, it is possible to calculate hydraulically for the pipeline using the short ΔT as it is needed for this case. At this, all additional capacity will be generated! Consequence: If the plausibility control is done for short pipe with large callibration, then, this method is not applied. Long calculation time for small ΔT or implicit solution method is essentially required.
What is the maximum number of iteration to be adjusted for implicit solution method?
With the implicit solution method, the hydraulic values (Water level, flow velocity etc.), in contrast to explicit solution method, are determined iteratively in each time step. The normal number of iterations stand between 30 and 50. The max. iteration should always be less than 100 . Practically,others may also find more than 100 iterations , for this "Further improvement" compensate the computation time.
Where is the difference between the explicit and the implicit solution method in terms of the convergence criterion?
With the explicit solution method, the convergence criterion refers to the volume error, which results from the computation with the impoundage. During the iterations the volume error is reduced, so as to maintain the convergence criterion. The default value for the convergence criterion amounts to 0.05 m³.
With the implicit solution method, the convergence criteria is to be given in percentage(decimal no. during the input). A value of 0.01 corresponds to 1%(default value). This percentage is used with the iterations for the examination of the water level and the velocity of flow. As soon as the difference is smaller, as the given criterion, the iteration of the current time step is terminated. If the computation does not fulfill the convergence criterion after the given number of iterations, then the values of the last iteration for the further computation are used.
How do I import the old project files of MS-DOS-KANAL or HYKAS (Version 8.0) to the current version of HYKAS-project?
First open the current HYKAS version with a new project with the menu optionFile | New. After this go with the menu option File | Import | Rehm-KANAL... (DOS / WIN). There, all projects existing in the selected drive are listed to appear in the dialog window. (The projects are recognized only if these are located in the original program directory of the previous versions \REHM\KANAL\KANALPRO). After the selection of a project, its data are transferred to the new project format (Microsoft Access-Database).
How do I get the data output in an ASCII-file?
Go through the menu like : File | Export | ASCII-File. The heading list is formatted previously with Table | Heading list . Optionally, additional catchment areas can also be exported. These are adjusted at the end of the file separately in a fixed format and are provided with a special line identification.
What is to be noted while importing data from an ASCII-File?
Use the menu file option File | Import | ASCII-File. Like before, the format notation here also serves to prepare the header list with menu option Table | Headlist.This head-list must be exactly co-ordinated with the file which is to be imported. Information about number of indications and/or right-of-comma positions is contained in the head-list declaration.
Why is the flow duration not being summed up in my hydraulic calculation?
Probably you might have assigned no catchment area to the concerned pipeline. The program regards such case as transportation collecting tanks, for which for the prevention of an undesired reduction of the time factor, which is not summed flow time. If you wish a summation nevertheless, you should assign as small a surface as possible to these pipes(e.g.: 0.001 hectars). Das Programm betrachtet solche Kanalhaltungen dann als Transportsammler, für welche zur Verhinderung einer ungewünschten Abminderung des Zeitbeiwertes, die Fließzeit nicht aufsummiert wird.
Data output: Single line words in the output list( Mainlist) are slightly above than the rest of the data.
The space requirement of the value which can be represented exceeds the permissible value. It is recommended that the width of the concerned columns be increased by Menu Table | Head-list, shifting the column dividing lines in the table head of the column head Head- list-Design.
Data Output: The numeric digit is entirely given by hyphon (–).
The space requirement of the value which can be represented exceeds the permissible value. As it concerns a negative number, only the minus sign remains visible, while the actual number disappears. It is recommended to maintain the column width with the concerned menu Table | Head-list, increase by shifting the column dividing lines in the table head of the column headHead-list-Design.
Login-Window displays in starting HYKAS .
Possible reasons:
| • | The program might not have properly closed. |
| • | There might be a problem while accessing the database. |
Solution: Confirm Login with the standard username: "Admin" . Click on the corresponding check boxes that the Login-window will not be displayed in the future & then click on OK.
Unsteady calculation: In the output list, there are negative discharge displayed.
Negative discharges indicate a reverse direction of flow. Frequently these negative discharges form even the maximum discharge within a pipeline. A cause is often a static water level produced by the given impoundage depth at a free discharge opening in the appropriate or one of the following pipes.
Steady calculation: Branching in the flow directions do not converge.
It occurs again and again that the program cannot stop agreeing head of water for both outgoing pipelines at the distributor during the iterative quantity of water distribution at bypasses into direction of flow. Around a possible convergence to favour secured flowing discharge should not prevail, it should resoling jumps occur and the attitudes concerned should than existence be defined in the three attitudes attached at the distributor pit. If the iteration do not converge , the splitting off of the bypass with pre-defined quantity of water distribution is recommended:
| • | Name the outer bounded manhole by the pipelines, so that no connection with the distributer manhole exists. |
| • | Declare the distribution manholes as acording to the rain-water capacity with a new definition as water volume release. |
| • | Illustrate the similarities between the water quantity of pipe with the new manhole named as "Constant Rain water discharge". |
| • | Start the hydraulic calculation and check the water level in both the manholes. Alternatively, the disburdened manhole for e.g. inflow water volume upto ... |
Collect the data from profile for the calculation of partial filling tables. Welcher Zusammenhang besteht zwischen der Profilhöhe des tatsächlichen Rohres und der Höhe des durch Koordinaten zu erfassenden Musterprofiles.
Es besteht überhaupt kein Zusammenhang. Die einzige Vorraussetzung für übereinstimmende Teilfüllungstabellen ist die geometrische Ähnlichkeit zweier Profilquerschnitte. Geometrisch ähnlich sind sich zwei Profile, wenn bei identischer Profilform, die Profilhöhen und die Profilbreiten proportional zueinander sind. Einleuchtendes Beispiel: Ein Kreisprofil DN200 hat die gleiche Teilfüllungskurve wie ein Kreisprofil DN1500. Es empfiehlt sich bei der Erfassung der Profilkoordinaten eines Sonderprofiles der Einfachheit halber eine Einheitsprofilhöhe von 1,0 zu verwenden was jedoch nicht zwingend erforderlich ist.
Why is my pipeline überstaut only have only load factor like 37%?
Die Haltung ist aufgrund eines Rückstaues ein- bzw. überstaut. Der Belastungsgrad wird anhand der in Fließrichtung abflaufenden Wassermengen ermittelt.
KAREL
How can the data from the reference table in the query be used?
Zu vielen Daten findet man in der Projektdatenbank nur eine Kennziffer (z.B. Straßenschlüssel, Kanalart usw.). Der eigentliche Wert (Hauptstraße, KR-Regenwasser usw.) steht jedoch in der Referenzdatenbank. Um Tabellen aus der Referenzdatenbank mit der Projektdatenbank zu verknüpfen, öffnen Sie zunächst die Projektdatenbank (Projektname.rdb) mit Microsoft Access. Anschließend können Sie über den Menüpunkt Datei | Externe Daten | Tabellen verknüpfen die Referenzdatenbank auswählen. Markieren Sie die Tabellen, die Sie mit der Projektdatenbank verknüpfen möchten. Die verknüpften Tabellen erscheinen anschließend in der Tabellenansicht der Projektdatenbank und können genauso wie die internen Tabellen verwendet werden. Zur Unterscheidung sind die verknüpften Tabellen mit einem Pfeil gekennzeichnet. Mit dem Tabellenverknüpfungsmanager von Access kann der Pfad für die Referenzdatenbank jederzeit verändert werden.
How does the KAREL-projekt work?
Ein KAREL-Projekt setzt sich aus 3 Datenbanken zusammen: der eigentlichen Projektdatenbank, mit der Erweiterung .rdb, sowie der Referenz- und der Adressdatenbank. Beim Neuanlegen eines Projektes müssen Sie zunächst den Pfad der zum Projekt gehörigen Referenz- und Adressdatenbank festlegen. Diese Informationen werden in der Projektdatenbank abgespeichert, so dass beim erneuten Öffnen des Projektes automatisch die richtige Referenz- und Adressdatenbank geöffnet wird. Wurden die Referenzdatenbanken in ein anderes Verzeichnis verschoben, so stimmen diese Pfadangaben nicht mehr und müssen neu festgelegt werden.
With KAREL, how can we prepare the inquiry report of the pipe reports?
Einfache Berichte können mit dem Abfrage- und Berichtgenerator von KAREL erzeugt werden. Komplexe und umfangreiche Berichte sollten direkt mit Microsoft Access entwickelt werden. Grundlage für jeden Bericht ist eine Abfrage, in der alle Datenfelder enthalten sind, die später im Bericht erscheinen sollen. Basierend auf dieser Abfrage können mit dem Berichtgenerator in KAREL bzw. mit dem Berichtsassistenten in Access komfortable Berichte erstellt werden.
REBECK
Which iteration method should I select for the calculation of precipitation depth?
Precipitation depth table computation
Die Niederschlagshöhen werden aus jeweils 4 Stützstellen, die dem KOSTRA-Atlas (KOSTRA-DWD bzw. KOSTRA-DWD-2000) zu entnehmen sind, interpoliert. Inzwischen hat das Interpolationsverfahren für den Bereich I (Stützstellen D=15 und D= 60 Minuten) gewechselt:
1997 wurde vom DWD für u(D) und w(D) für alle Bereiche die doppeltlogarithmische Interpolation vorgeschrieben. Sie führt im Bereich bis D=15 Minuten im Vergleich zu den anderen Interpolationsverfahren zu den höchsten Regenspenden.
Im Fortschreibungsbericht des Deutschen Wetterdienstes (DWD) wurde im November 2005 eine "kombinierte" Interpolationsart zur Berechnung der KOSTRA-Niederschlagshöhen veröffentlicht. Demnach gilt für den Kurzzeitbereich (Bereich I, D = 5 bis D = 60 Minuten) der hyperbolischen Parameterausgleich für u(D) und den doppeltlogarithmische Parameterausgleich für w(D). Von Rebeck wird diese Interpolationsart als KOSTRA-DWD-2000 bezeichnet.
The rainfall depth in the area II und III will be further interpolaed by double logarithmic method.
Is it possible to export the result list?
Yes, since the program version 9.1, the following export functions can be used:
Various export options in REBECK
| • | Clipboard in ASCII - Text
The text of the current page will be copied in the clipboard as ASCII-Text.
Tip: The texts can be pressed by Shift-key and marked with the left mouse button. These marked portions are disposed in the clipboard. |
| • | Clipboard in WMF- Format
The active page will be copied in the clipboard as a vector data. |
| • | RTF-Export
All the pages will be saved in the form of RTF-files. After the input of the filenames, the files will be opened. The associated program (Word, WordPad, etc...) will open the files with System setting (Öpen with...) . |
| • | HTML-Export
All the pages will be saved in the HTML-files. After providing the filenames, the files will be opened. They can be opened by the associated programs (Internet Explorer, Mozilla Firefox, etc...) with the system setting(Open with...). |
RS138
Which iteration procedure should I use for the calculation of KOSTRA-Precipitation depth ?
Die Niederschlagshöhen werden aus jeweils 4 Stützstellen, die dem KOSTRA-Atlas (KOSTRA-DWD bzw. KOSTRA-DWD-2000) zu entnehmen sind, interpoliert. Inzwischen hat das Interpolationsverfahren für den Bereich I (Stützstellen D=15 und D= 60 Minuten) gewechselt:
1997 wurde vom DWD für u(D) und w(D) für alle Bereiche die doppeltlogarithmische Interpolation vorgeschrieben. Sie führt im Bereich bis D=15 Minuten im Vergleich zu den anderen Interpolationsverfahren zu den höchsten Regenspenden.
Im Fortschreibungsbericht des Deutschen Wetterdienstes (DWD) wurde im November 2005 eine "kombinierte" Interpolationsart zur Berechnung der KOSTRA-Niederschlagshöhen veröffentlicht. Demnach gilt für den Kurzzeitbereich (Bereich I) der hyperbolischen Parameterausgleich für u(D) und den doppeltlogarithmische Parameterausgleich für w(D). Von RS138 wird diese Interpolationsart als KOSTRA-DWD-2000 bezeichnet.